MODEL:  TUK-4020

CAPACITY:  40 Amp - 90-280 Vac / 47-63 Hz

AMP-IT-UP! Each model packs a powerful universal automatic Battery Maintenance System (90-280Vac, 47-63 Hz) in an ultra-compact, lightweight package.

Product Description

Technocrat IT battery Buff are highly versatile and can be mounted in multiple positions, thanks to their inherent Flexible design characteristics. Technocrat IT Battery Buff delivers Heavy Duty Charging capability, Battery Equalization, outstanding low electrical interference, coupled with efficient, power factor corrected, multistage charging capability. Installation is a breeze, thanks to the easy-access AC and DC wiring compartments and the easy-to-read display.

NEW PARALLEL FEATURE
Technocrat IT  12-Volt / 24-volt Battery Buff are available with parallel stacking feature which allows you to double the output current when used in parallel.

u  Software and CPU controlled Bulk charging, maintenance, optimization and protection

u  Three stages variable charging voltage algorithm by timing for maximizing the battery lifetime.

u  Large charging capacity design (40Amp for 12Vdc mode; 20Amp for 24Vdc mode) for shortening the charging time.

u  Selectable charging currents base on connected battery capacity for extending the battery lifetime with suitable charging current.

u  Multiple voltages charging design for protecting diverse types of batteries of Flooded Lead-Acid, Gel, and AGM chemistries batteries.

u  Any quality of Power:Wider input voltage range from 90Vac to 280Vac for universal input, also compatible with a generator or other low-quality power sources

u  High AC to DC converting efficiency design (higher than 80%)

u  Smart fan control for maximizing the performance and fan lifetime.

u  Active equalization technique based on flash micro-controller. 

u  Reduces the battery replacement which again greatly reduces the cost. 

u  Easy to install with batteries connected in series. 

u  Suitable for N numbers of batteries by utilizing multiple units together. 

u  Extends battery life and run time by upto 5 times

u  Prevents over and under charge due to battery imbalance.

 

Buff Building Blocks

There are three main objectives common to Battery Buff System

u  Protect the cells or the battery from damage

u  Prolong the life of the battery

u  Maintain the battery in a state in which it can fulfill the functional requirements of the application for which it was specified

 

 

Applications

  •  Inverters
  • Home UPS Systems
  • Solar Systems
  • UPS Systems
  • Telecommunications
  •  Yatch / Marine / Boats
  • Trains
  •  Industrial Machines (e.g. Folklifts,Cranes)
  •  Electric Golf carts

 

 
WHAT MAKES TECHNOCRAT IT BATTERY BUFF SO IMPORTANT:

Despite all the technical automations put into Technocrat IT Battery buff, we shall analyze just one of the many to show the greatness in the product design:

Most inverters, UPS, boat charger, alternators e.t.c charge any battery connected to them.
However, Charging mechanism of most Charging systems are generic, and since they do not know which battery would be connected they charge very well assuming the batteries are standard batteries. (Without a battery type selector, the manufacturer has to assume standard batteries to avoid overcharging that can damage or explode batteries.).

However, different types of batteries have their uniqueness and require distinct charging methods. This can best be understood by their full charge stage voltages. (Only measure full charge cvoltage after the battery has been off-load/idle for over 3 hours and open circuit.).

DEEP CYCLE BATTERIES ARE VERY DIFFERENT FROM REGULAR BATTERIES:

Comparison of Battery State-of-Chart to Open Circuit Voltage for 12-Volt DEEP CYCLE Batteries

% Charge

FLA

Gel

AGM

100

12.70-12.60

12.95-12.85

12.90-12.80

75

12.40

12.65

12.60

50

12.20

12.35

12.30

25

12.00

12.00

12.00

0

11.80

11.80

11.80

 

STANDARD BATTERIES:
State of Charge 12 Volt battery Volts per Cell
100% 12.7 2.12
90% 12.5 2.08
80% 12.42 2.07
70% 12.32 2.05
60% 12.20 2.03
50% 12.06 2.01
40% 11.9 1.98
30% 11.75 1.96
20% 11.58 1.93
10% 11.31 1.89
0 10.5 1.75



NOTICE: When a standard battery is 12.00 Volt, it is still 60% charged, while a deep cycle at 12Volt is only 25% charged.

Even for deep cycles, 12.6Volts of AGM is 75% charged, while the same voltage for flooded is 100%.

What this means is that Technocrat IT Automatic Battery buff will ensure your batteries are always 100% charged (with No-Overcharge) while the normal chargers or those that come with the Inverters, UPS e.t.c. or any other charging system would only keep your batteries between 50-75% charged. In the short term, this affects how long your battery will last before being fully discharged by a factor of 2 to 5 times. In the long term, this alone makes Technocrat ITbattery Buff extend battery life by upto 5 times more both short term and long term. Click here to go to relevant portion of our FAQ to see how it affects battery life.